Real energy measurement of two equal solar panels (fixed and motorized) Two equal solar panels were exposed to the real sun and conversed electrical power was measured.
Test conditions: Solar panels (both): 50W (producer spec. at AM 1.5) Date: July 2005 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear
Results: Average energy of fixed: 209,2Wh Average energy of motorized: 338,5Wh Note: sum of motor energy consumption through all day is 0.0832Wh or 0.025% of all collected energy.
Efficiency of motorized panel: 161,8%
 |
|