Home page
> SOLAR TRACKERS
> SOLAR TRACKERS
> Solar Motor Sun Tracer SM12SLT 1-axis with backstructure for 12 panels (2,16 kWp)
| SunTracer Family comparison (review betwen models) |
| Number of turning axis |
1 |
| Hour angle |
100º |
| Elevation angle |
/ |
| Tracking accuracy |
<0.5˚ (<0.1˚ ****) |
| Operating protocol |
TdAPS (Time derived Astronomical Positioning System) |
| Type of positioner |
Servo driver positioner with TdAPS arc logic function calculation |
| Type of timer |
GMT clock with EOT and calendar |
| Type of communication interface |
USB interface |
| Networking solution for control from centre |
CAN BUS **** |
| Type of application program for supervision and setting |
Solar tracking system |
| Motor power supply |
24 VDC ±15% (5 A current capacity) |
| Turning time interval |
1 minute (0.25°) |
| Operating temperature |
-25°C to +85°C |
| Max. safe wind speed |
<180km/h (tested up to 230km/h and all ok) |
| Estimated service life |
10.000 turns of 200° (100°E + 100°W), or 20 years - |
| Operation at humidity |
0% to 100%, relative humidity |
| Backup battery |
/ |
| Setting and changing data via PC |
/ |
| Monitoring possibility via PC |
/ |
| Moved on the position sent from PC |
/ |
| Upgrading possibility via PC |
/ |
| Options ( **** for additional payment ) |
Options marked **** are for additional payment |
| Anti-shadowing function |
/ |
| Type of hour-angle engine |
/ |
| Final stage of gear at hour-angle shaft |
/ |
| Hour-angle shaft diameter and length |
/ |
| Turning speed of hour angle shaft |
/ |
| Max. dynamic torque of the hour-angle shaft |
8000N |
| Max. consumption during the operation of the hour-angle shaft |
4A @ 4780Nm |
| Destructive torque of the hour-angle output shaft |
>9000Nm |
| Type of elevation shaft and stroke |
/ |
| Turning speed of elevation shaft |
/ |
| Max. torque of elevation shaft |
/ |
| Max. current of elevation shaft |
/ |
| Destructive torque of elevation shaft |
/ |
| Standby consumption (when is not moving) |
/ |
| Power supply connection |
2 cables with an internal Cu conductor of 1.5mm2 |
| Arm width |
/ |
| Type of backstructure clamp |
C- clamp griper |
| Tube diameter for mounting |
/ |
| Dimensions of a PV panel |
12 pieces of 0.99m x 1.68m in total 20m2 |
| Weight of a PV panel |
12 pcs per 25kg |
| Dimensions of a packed product |
1 box of 5m(L) x 0.5m(W) x 0.5m(H) |
| Product weight |
250kg |
| Internal power battery for return at evening |
/ |
| Type of charging circuit if build in |
/ |
| Maximum charging current |
/ |
| Battery hysteresis of charging |
/ |
| Load hysteresis of discharging |
/ |
| Type of solar connectors (if needed) |
/ |
|
1 axis or dual axis Solar
Tracker with accuracy better than 0,5 deg and backstructure for 12 pieces
of solar panels dimensions 0,82 m x 1,604 m and weight of 25 kg max
each. So together for 20m2 solar panel surface. A Suitable for PV panels,
concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses,
trafic signalisations, street light, cottages, small and large powerplants where
solar panels are connected in serial and output is connected directly to
inverter or an external charging device. Wind resistance is minimal
180km/h.
Solar tracker anti-shadowing software
function included.
Real energy measurement of two equal solar panels (fixed and
motorized)
- Three equal solar panels were exposed to the real
sun and conversed electrical power was measured.
- Test conditions:
- Solar panels (all):
2160W (producer spec. at AM 1.5)
- Date:
July 2009
- Time:
4:00 to 20:00 (sun time)
- Geo.
Latitude: 46°
N
- Weather conditions: sunny, but not totally
clear
- Results:
- Average energy of
fixed: 9028.8Wh
- Average energy of
motorized: 14623.2Wh
- Note: sum of motor energy consumption through all day
is 35.5Wh or 0.24% of all collected energy.
Efficiency of motorized panel:
161,6%

- Graphic chart of the motor dinamic and
static torque

|
Solar Motor
"SunTracer 2-axis with backstr. for 2 panels" / SM34SPMV2P /
383106390111 |

|
|
Instructions for
installation and use in PDF format |
|
| -
English user manual in PDF format - the latest |
Download |
|
- English user manual in PDF format - previous |
Download |
|
- French user manual
in PDF format |
Download |
|
- German user manual in PDF
format |
Download |
|
- Italian user manual in PDF
format |
Download |
|
- Slovenian user manual in
PDF format - the latest!! |
Download |
|
- Spanish user manual in PDF
format |
Download |
|
Leaflets |
|
|
- English leaflet in PDF format
medium resolution |
Download |
|
- English leaflet in PDF format
low resolution |
Download |
|
The
latest firmware |
|
|
Please, browse on support
page |
|
|
|
|
|
Certificates |
|
|
- Declaration of Conformity in
PDF format |
Download |

 |
| |
| |
| |
| |
| |
|

Dear Customers,
We would like to express you our utmost gratitude to take opportunity to visit us in Munich, Germany for the Intersolar Europe 2010 at the New Munich Trade fair Centre in our booths: Hall A3, 538 and FG 145.
We were..... read more ===>
------------------------------------ |

|
|