| |
Home page
> SOLAR TRACKERS
> SOLAR TRACKERS
> Solar Motor Suntracer 2-axis with backstructure SM34SPM+ / 383106390118 (0,2kWp)
| Number of votes: 27, Total vote: 3.4 |
|
|
| SunTracer Family comparison (review betwen models) |
| Number of turning axis |
2-axis |
| Hour angle |
96° typical / 100° max., software and hardware limit |
| Elevation angle |
125°, software and hardware limit |
| Tracking accuracy |
<0.5° (<0.1° ****) |
| Operating protocol |
TdAPS (Time derived Astronomical Positioning System) |
| Type of positioner |
Servo driver positioner with TdAPS arc logic function calculation |
| Type of timer |
GMT clock with EOT and calendar |
| Type of communication interface |
USB interface since beginning of the January 2010, before RS232 |
| Networking solution for control from centre |
CAN BUS **** |
| Type of application program for supervision and setting |
Solar tracking system monitor via web site |
| Motor power supply |
24 VDC (working from 12 to 69 VDC), (2,5A current capacity @12V) |
| Turning time interval |
1 minute (0.25°) |
| Operating temperature |
-20°C to +70°C |
| Max. safe wind speed |
<130km/h (tested up to 180km/h and all ok) |
| Estimated service life |
5.000 turns of 200° (100°E + 100°W), or 10 years |
| Operation at humidity |
0% to 100%, relative humidity |
| Backup battery |
Backup for timer, position and data |
| Setting and changing data via PC |
Yes, It can be setup 1000 parameters |
| Monitoring possibility via PC |
Yes, It can be monitored 1000 parameters |
| Moved on the position sent from PC |
Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC |
| Upgrading possibility via PC |
Yes, firmware via PC with help of web wizard |
| Options ( **** for additional payment ) |
Heliostat, can be used, **** |
| Anti-shadowing function |
Yes, included only specify the hour angle tracking size and E-W raster of grid |
| Type of hour-angle engine |
Servo motor with position encoder on cogwheel |
| Final stage of gear at hour-angle shaft |
steel worm wheel |
| Hour-angle shaft diameter and length |
Ø40 mm, L=1150mm (steel) |
| Turning speed of hour angle shaft |
0,5°/s ±25% @ 24V at no load |
| Max. dynamic torque of the hour-angle shaft |
65Nm |
| Max. consumption during the operation of the hour-angle shaft |
500mA @ 65Nm |
| Destructive torque of the hour-angle output shaft |
>200Nm |
| Type of elevation shaft and stroke |
Linear motor SM4S520-V1 with stroke of 520mm |
| Turning speed of elevation shaft |
0.19°/s average ±25% @ 24V @ no load) |
| Max. torque of elevation shaft |
127.4Nm |
| Max. current of elevation shaft |
500mA @ 127.4Nm |
| Destructive torque of elevation shaft |
>1000Nm |
| Standby consumption (when is not moving) |
35mA ±25% @ 24V |
| Power supply connection |
2 cables with an internal Cu conductor of 1.0mm2 |
| Arm width |
1000 mm |
| Type of backstructure clamp |
Toothed scissors gripers - 4 pcs |
| Tube diameter for mounting |
60,3 mm |
| Dimensions of a PV panel |
2m x 1m (Alu. structure), for panels up to 2m2 |
| Weight of a PV panel |
25 kg |
| Dimensions of a packed product |
1200(L) x 200(W) x 200(H) mm |
| Product weight |
15kg |
| Internal power battery for return at evening |
/ |
| Type of charging circuit if build in |
/ |
| Maximum charging current |
/ |
| Battery hysteresis of charging |
/ |
| Load hysteresis of discharging |
/ |
| Type of solar connectors (if needed) |
/ |
|
2 axis or dual axis Solar
Tracker with accuracy better than 0,5 deg. A Suitable for PV panels,
concentrators - CPV, heliostats. Up to dimensions 2m x 1m usage at homes on-grid
at roof on houses, for trafic signalisation, for street light use, for power
suplly at cottages, for small and large powerplants where solar panels are
connected in serial and output is connected directly to inverter or an external
charging device. Wind resistance is minimal 130km/h. In a Year basis with
2 axis motor you can get 7% more income of energycompared to single axis
motor.
Solar tracker anti-shadowing software
function included.
Real energy measurement of two equal solar panels (fixed and
motorized)
- Two equal solar panels were exposed to the real sun and
conversed electrical power was measured.
- Test conditions:
- Solar panels (both): 200W (producer
spec. at AM 1.5)
- Date:
July 2005
- Time:
4:00 to 20:00 (sun time)
- Geo.
Latitude: 46°
N
- Weather conditions: sunny, but not totally
clear
- Results:
- Average energy of fixed:
836,0Wh
- Average energy of
motorized: 1354,0Wh
- Note: sum of motor energy consumption through all day
is 20Wh or 1.48% of all collected energy.
Efficiency of motorized panel:
160%



|
Solar Motor
"SunTracer 2X+" / SM34SPM+ / 383106390118 |

|
|
Instructions for
installation and use in PDF format |
|
| -
English user manual in PDF format - the latest |
Download |
|
- English user manual in PDF format - previous |
Download |
|
- French user manual
in PDF format |
Download |
|
- German user manual in PDF
format |
Download |
|
- Italian user manual in PDF
format |
Download |
|
- Slovenian user manual in
PDF format - the latest!! |
Download |
|
- Spanish user manual in PDF
format |
Download |
|
Leaflets |
|
|
- English leaflet in PDF format
medium resolution |
Download |
|
- English leaflet in PDF
format low resolution |
Download |
|
The
latest firmware |
|
|
Please, browse on support
page |
|
|
|
|
|
Certificates |
|
|
- Declaration of Conformity in
PDF format |
Download |
 |
| |
| |
| |
| |
| |
|

Dear Customers,
We would like to express you our utmost gratitude to take opportunity to visit us in Munich, Germany for the Intersolar Europe 2010 at the New Munich Trade fair Centre in our booths: Hall A3, 538 and FG 145.
We were..... read more ===>
------------------------------------ |

|
|